Distribution Transformer

Discover the exceptional quality of our Distribution Transformer, meticulously sourced and traded by our team of experienced suppliers, dealers, and distributors with over 1 year of industry expertise. We offer a peerless range including the 3 Phase 200kVA Oil Cooled Distribution Transformer, 800kVA 3-Phase Oil Cooled Distribution Transformer, Furnace HT Transformer, 1500kVA 3-Phase Oil Cooled Distribution Transformer, and the 1600kVA 3-Phase Oil Cooled Distribution Transformer, all designed for optimum performance in diverse distribution applications. Get higher energy efficiency, robust overload capacities, advanced insulation, minimal maintenance needs, and magnificent voltage regulation compared to conventional transformers. Our products ensure reliability for all power needs, making them ideal for industries seeking unparalleled operational continuity. With supply ability spanning All India, seize this limited time to enhance your infrastructure with the superlative technology and durability our transformers deliver. Don't miss out-our stock is limited for customers aiming for the best in class, high-performance solutions for electrical distribution. Choose our Distribution Transformer solutions for safe, reliable, and long-lasting service that stands above the rest.

2.5MVA 3-Phase Oil Cooled Distribution Transformer

Price 2700000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 2.5MVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Double wound
  • Coil Structure
  • Laminated Core
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 2400x1300x1800 mm
  • Efficiency
  • Above 98%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • Max. 8700 W
  • Low Voltage
  • 433V
  • Material
  • Copper
  • Operating Temperature
  • -20C to 45C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 2.5MVA
  • Product Type
  • Other, Oil Cooled Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution of electrical power
  • Voltage Booster Type
  • Other, Off-circuit tap changer
  • Weight
  • Approx. 3500 kg

2MVA 3 Phase Oil Cooled Distribution Transformer

Price 2300000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 2MVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Double Winding
  • Coil Structure
  • Other, Layered Coil
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 2500 x 1500 x 1800 mm
  • Efficiency
  • Up to 98%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • 13 kW (at full load)
  • Low Voltage
  • 433V
  • Material
  • Steel Body, Copper Winding
  • Operating Temperature
  • -20C to +50C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 2MVA
  • Product Type
  • Other, Oil Cooled Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution
  • Voltage Booster Type
  • Other, Off Circuit Tap Changer (OCTC)
  • Weight
  • Approx. 4000 kg

3 Phase 200kVA Oil Cooled Distribution Transformer

Price 250000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 200kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Double Winding
  • Coil Structure
  • Laminated Core
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 1900x900x1600 mm
  • Efficiency
  • 98.5%
  • Frequency (MHz)
  • 50
  • High Voltage
  • 11kV
  • Load Loss
  • Max 1500 W
  • Low Voltage
  • 433V
  • Material
  • Copper
  • Operating Temperature
  • -25C to +50C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 200kVA
  • Product Type
  • Other, Oil Cooled Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution
  • Voltage Booster Type
  • Other, On Load Tap Changer
  • Weight
  • Approx. 1200 kg

250kVA Three Phase Oil Cooled Distribution Transformer

Price 315000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 250kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Double Winding
  • Coil Structure
  • Other, Core type
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 1850 x 850 x 1650 mm
  • Efficiency
  • Above 98%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • 2.1 kW at 75C
  • Low Voltage
  • 433V
  • Material
  • Copper
  • Operating Temperature
  • -5C to +50C
  • Output
  • 433V
  • Phase
  • Three Phase
  • Power Scope
  • 250kVA
  • Product Type
  • Other, Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Power Distribution
  • Voltage Booster Type
  • Other, On-load tap changer
  • Weight
  • Approx. 1200 kg

315kVA Three Phase Oil Cooled Distribution Transformers

Price 420000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 315kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Double Winding
  • Coil Structure
  • Laminated Core
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • Approx. 1900x800x1600 mm
  • Efficiency
  • 99%
  • Frequency (MHz)
  • 50
  • High Voltage
  • 11kV
  • Load Loss
  • As per IS-1180
  • Low Voltage
  • 433V
  • Material
  • Copper
  • Operating Temperature
  • -25C to +45C
  • Output
  • 433V
  • Phase
  • Three Phase
  • Power Scope
  • 315kVA
  • Product Type
  • Other, Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Power Distribution
  • Voltage Booster Type
  • Other, On Load Tap Changer (optional)
  • Weight
  • Approx. 1700 kg

400kVA 3-Phase Oil Cooled Distribution Transformers

Price 550000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 400kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Two
  • Coil Structure
  • Other, Double Wound
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 1850 x 850 x 1700 mm
  • Efficiency
  • Above 98%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • 4.2 kW (at full load)
  • Low Voltage
  • 433V
  • Material
  • Copper
  • Operating Temperature
  • -20C to 50C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 400kVA
  • Product Type
  • Other, Oil Cooled Distribution Transformer
  • Rated Voltage
  • 11kV / 433V
  • Standard
  • IS-1180
  • Usage
  • Distribution
  • Voltage Booster Type
  • Other, On-load tap changer (optional)
  • Weight
  • Approx. 1800 kg

500kVA Three Phase Oil Cooled Distribution Transformer

Price 650000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 500kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Double Winding
  • Coil Structure
  • Toroidal
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 2500 x 1300 x 1600 mm
  • Efficiency
  • High Efficiency
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • 3650 W
  • Low Voltage
  • 433V
  • Material
  • Steel Body, Copper Winding
  • Operating Temperature
  • -10C to 50C
  • Output
  • 433V
  • Phase
  • Three Phase
  • Power Scope
  • 500kVA
  • Product Type
  • Other, Oil Cooled Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution Transformer
  • Voltage Booster Type
  • Other, On-Load Tap Changer
  • Weight
  • Approximately 2500 kg

630kVA 3-Phase Oil Cooled Distribution Transformer

Price 810000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 630kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, 2
  • Coil Structure
  • Other, Layer wound
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 1850 x 950 x 1370 mm
  • Efficiency
  • >=98.5%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • Approx. 2650 W
  • Low Voltage
  • 433V
  • Material
  • Mild steel tank, copper winding
  • Operating Temperature
  • -10C to 50C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 630kVA
  • Product Type
  • Other, Oil Cooled Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Power distribution
  • Voltage Booster Type
  • Other, Off-circuit tap changer
  • Weight
  • Approx. 1850 kg

750kVA 3-Phase Oil Cooled Distribution Transformers

Price 920000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 750kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, 2
  • Coil Structure
  • Other, Layer wound
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 2000 x 1100 x 1800 mm
  • Efficiency
  • Approx. 98%
  • Frequency (MHz)
  • 50
  • High Voltage
  • 11kV
  • Load Loss
  • Approx. 6300 W at full load
  • Low Voltage
  • 433V
  • Material
  • Steel body, copper winding
  • Operating Temperature
  • -25C to +45C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 750 kVA
  • Product Type
  • Other, Oil Cooled Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution transformer for electrical networks
  • Voltage Booster Type
  • Other, On-load Tap Changer available
  • Weight
  • Approx. 3000 kg

800kVA 3-Phase Oil Cooled Distribution Transformer

Price 1010000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 800kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Double wound
  • Coil Structure
  • Other, Layered winding
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • Approx. 2200x1050x1850 mm
  • Efficiency
  • 98%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • 7100 W
  • Low Voltage
  • 433V
  • Material
  • Steel body, Copper winding
  • Operating Temperature
  • -25C to +45C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 800kVA
  • Product Type
  • Other, Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution
  • Voltage Booster Type
  • Other, On-load tap changer
  • Weight
  • Approx. 2500 kg

1000kVA 3-Phase Oil Cooled Distribution Transformer

Price 1200000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 1000 kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Double Winding
  • Coil Structure
  • Laminated Core
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 2100 x 1100 x 1800 mm
  • Efficiency
  • 98.5%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11,000V
  • Load Loss
  • 6.8 kW at full load
  • Low Voltage
  • 433V
  • Material
  • Copper and Steel
  • Operating Temperature
  • -20C to 50C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 1000 kVA
  • Product Type
  • Other, Oil Cooled Distribution Transformer
  • Rated Voltage
  • 11kV
  • Standard
  • IS-1180
  • Usage
  • Distribution of electrical power
  • Voltage Booster Type
  • Other, OLTC/Off Circuit Tap Changer
  • Weight
  • Approximately 2800 kg

1250kVA 3-Phase Oil Cooled Distribution Transformer

Price 1400000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 1250 kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Dual winding
  • Coil Structure
  • Laminated Core
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • Approx. 2650 x 1450 x 1650 mm
  • Efficiency
  • Above 98%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • Max 7750W
  • Low Voltage
  • 433V
  • Material
  • Copper
  • Operating Temperature
  • -20C to 45C
  • Output
  • 1250 kVA
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 1250kVA
  • Product Type
  • Other, Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Power distribution
  • Voltage Booster Type
  • Other, On-Load Tap Changer (OLTC)
  • Weight
  • Approx. 4100 kg

1500kVA 3-Phase Oil Cooled Distribution Transformer

Price 1800000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 1500kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Two coils per phase
  • Coil Structure
  • Other, Double Wound
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 2650 x 1200 x 2200 mm
  • Efficiency
  • >98%
  • Frequency (MHz)
  • 50
  • High Voltage
  • 11kV
  • Load Loss
  • As per IS-1180
  • Low Voltage
  • 433V
  • Material
  • Copper
  • Operating Temperature
  • -10C to 45C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 1500kVA
  • Product Type
  • Other, Oil Cooled Distribution Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution of electrical energy
  • Voltage Booster Type
  • Other, Off-circuit tap changer
  • Weight
  • Approx. 4800 kg

1600kVA 3-Phase Oil Cooled Distribution Transformer

Price 2000000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 1600kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, 2
  • Coil Structure
  • Other, Layer Wound
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • 2850mm x 1550mm x 1800mm
  • Efficiency
  • Above 98%
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11kV
  • Load Loss
  • 4.2 kW (at full load)
  • Low Voltage
  • 433V
  • Material
  • Mild Steel Body, Copper Winding
  • Operating Temperature
  • -25C to +50C
  • Output
  • 433V
  • Phase
  • Other, 3-Phase
  • Power Scope
  • 1600kVA
  • Product Type
  • Other, Oil Cooled Transformer
  • Rated Voltage
  • 11kV/433V
  • Standard
  • IS-1180
  • Usage
  • Distribution Transformer
  • Voltage Booster Type
  • Other, On-load tap changer (optional)
  • Weight
  • Approx. 3500 kg

Furnace HT Transformer

Price 510000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • Large capacity
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Multiple coils
  • Coil Structure
  • Other, Core type
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • Customized dimensions
  • Efficiency
  • High efficiency
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • Customizable
  • Load Loss
  • Low load loss
  • Low Voltage
  • Customizable
  • Material
  • Cast Iron
  • Operating Temperature
  • 0 to 50 Degree C
  • Output
  • Depends on application
  • Phase
  • Three Phase
  • Power Scope
  • High power scope
  • Product Type
  • Other, Furnace HT Transformer
  • Rated Voltage
  • High voltage rating
  • Standard
  • Industrial standard
  • Usage
  • Furnace applications
  • Voltage Booster Type
  • Other, Industrial booster type
  • Weight
  • Heavy duty

Oltc Distribution Transformer

Price 1000000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 400 kVA to 2500 kVA
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Two coils
  • Coil Structure
  • Other, Layer Wound
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • Custom as per rating
  • Efficiency
  • High efficiency
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11 kV/22 kV
  • Load Loss
  • As per IS 1180
  • Low Voltage
  • 433 V
  • Material
  • Metal
  • Operating Temperature
  • -25C to +50C
  • Output
  • Standard output
  • Phase
  • Three Phase
  • Power Scope
  • Up to 2.5 MVA
  • Product Type
  • Other, Oltc Distribution Transformer
  • Rated Voltage
  • 11 kV / 22 kV
  • Standard
  • IS 1180/IEC
  • Usage
  • Distribution of electrical power
  • Voltage Booster Type
  • Other, On-load tap changer
  • Weight
  • As per rating

Three Phase Distribution Transformers

Price 290000 INR/ Unit

MOQ : 1 Unit

  • Capacity
  • 200KVA & ONWARDS
  • Coil Material
  • Other , Copper
  • Coil Number
  • Other, Standard coil count
  • Coil Structure
  • Other, Core type
  • Cooling Type
  • Oil Cooled
  • Dimension (L*W*H)
  • As per rating
  • Efficiency
  • High efficiency
  • Frequency (MHz)
  • 50 Hz
  • High Voltage
  • 11-22-33 kV
  • Load Loss
  • Complies IS-1180 spec
  • Low Voltage
  • 415 V standard
  • Material
  • Copper
  • Operating Temperature
  • -10C to +55C
  • Output
  • Electric power general supply
  • Phase
  • Three Phase
  • Power Scope
  • 200KVA & ONWARDS
  • Product Type
  • Other, Three Phase Distribution Transformer
  • Rated Voltage
  • 11-22-33 kV
  • Standard
  • IS-1180
  • Usage
  • Distribution transformer for electrical networks
  • Voltage Booster Type
  • Other, Step-Down
  • Weight
  • Varies by capacity


Back to top